Thermo Scientific™ Orion™ Pro Star PH211 pH/ORP Bench Meter with Stand
Designed to provide accurate and reliable pH, ORP and temperature analysis, the Thermo Scientific™ Orion™ Pro Star PH211 bench meter is well suited for laboratories that desire a modern meter with advance performance.
Certifications/Conformité | CE, TUV 3-1, FCC classe A |
---|---|
Clavier | Capacitive touchscreen user interface |
Sélection de la température | Automatic with ATC temperature sensor, ambient or manual |
Gamme (rH) | -2000 to 2000 mV |
Précision (pH) | ±0.002 pH |
Garantie | 2 year meter warranty |
Dimensions (L x l x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
Adaptateur secteur | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
Measurement Modes | pH with mV and Temperature,ORP with mV and Temperature |
Canaux | 1 |
Point isopotentiel | 7.000 pH |
Langues | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
Modèle | PH211 |
Sorties | USB flash drive, computer or printer (STARA-106) |
Méthodes | 10 |
Indice IP | IP54 |
Points de données | 10,000 with Date and Time Stamp |
Points d’étalonnage (pH) | 1 à 5 points |
Poids (métrique) | 1.00 kg |
Sorties d’alarme | Calibration reminder alarm, high and low limit alarm per parameter |
Étalonnage de la sonde de température | 1 or 2 point temperature offset calibration |
Type de fonction d’enregistrement | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
Résolution (pH) | 0.1, 0.01 or 0.001 pH |
Précision (température) | ±0.3°C, ±0.5°F |
Entrées | BNC for pH or ORP, 8-pin MiniDIN for ATC, pin-tip for reference |
Étalonnage | pH, ORP, Temperature |
Gamme (mV) | –2000 à 2000 mV |
Type d’affichage | 7-in. High-resolution Color Graphic LCD |
Calibration Points | 1 to 5 (pH), 1 (ORP), 1 to 2 (Temperature) |
Gamme (mV relative) | -2000 to 2000 mV |
Mémoire | Non volatile |
Poids (impériale) | 2.20 lbs. |
Précision (mV) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
Plage de températures (métrique) | -30°C à +130°C |
Résolution (mV) | 0.1 mV |
Backlight Option | Oui |
Gamme (pH) | -2 à 20 |
Résolution (température) | 0,1°C, 0,1°F |
Plage de températures (impériale) | -22°F to +266°F |
Thermo Scientific™ Orion™ Pro Star DO213 Dissolved Oxygen Bench Meter
Designed to provide accurate and reliable dissolved oxygen, barometric pressure and temperature analysis, the Thermo Scientific™ Orion™ Pro Star DO213 bench meter is well suited for laboratories that desire a modern meter with advance performance.
Certifications/Conformité | CE, TUV 3-1, FCC Class A |
---|---|
Type de sonde | Polarographic or optical DO electrode |
Clavier | Capacitive touchscreen user interface |
Sélection de la température | Automatic with ATC temperature sensor, ambient or manual |
Résolution du coefficient de saturation (RDO) | 0.1, 1% saturation |
Correction de la pression barométrique | Yes, automatic with built-in barometer or manual |
Garantie | 2 year meter warranty |
Dimensions (L x l x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
Adaptateur secteur | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
Précision (OD par mesure polarographique) | ±2% saturation; ±0.02 mg/L or ppm |
Measurement Modes | Dissolved Oxygen (mg/L with Temperature and Barometric Pressure),Dissolved Oxygen (ppm with Temperature and Barometric Pressure),Dissolved Oxygen (% Saturation with Temperature and Barometric Pressure) |
Canaux | 1 |
Langues | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
Résolution (OD) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
Modèle | DO213 |
Option de rétro-éclairage | Oui |
Sorties | USB flash drive, computer or printer (STARA-106) |
Méthodes | 10 |
Indice IP | IP54 |
Gamme (OD par mesure polarographique) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
Percent Saturation Relative Accuracy (Polarographic DO) | ±2% saturation |
Points de données | 10,000 with Date and Time Stamp |
Poids (métrique) | 1.00 kg |
Gamme de pression | 400,0 à 850,0 mmHg ; 0,533 à 1,133 bar |
Gamme (OD) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
Sorties d’alarme | Calibration reminder alarm, high and low limit alarm per parameter |
Étalonnage de la sonde de température | 1 or 2 point temperature offset calibration |
Type de fonction d’enregistrement | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
Percent Saturation Range Polarographic DO | 0.0 to 600.0% saturation |
Précision (température) | ±0,3°C ±, 0,5°F |
Modes d’étalonnage | Water-saturated air (100% and 0% saturation), air-saturated water (100% and 0% saturation) or custom concentration value (Winkler) |
Résolution (OD par mesure polarographique) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
Entrées | 9-pin MiniDIN for dissolved oxygen with ATC |
Type d’affichage | 7-in. High-resolution Color Graphic LCD |
Gamme (RDO) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
Mémoire | Non volatile |
Précision (DO) | ±2% saturation; ±0.02 mg/L or ppm |
Plage (métrique) de températures | -30.0°C to +130.0°C |
Précision (baromètre) | ±6.0 mmHg; ±0.008 bar |
Percent Saturation Resolution (Polarographic DO) | 0.1, 1% saturation |
Poids (impériale) | 2.20 lbs. |
Résolution (RDO) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
Gamme d’humidité relative | 5 à 85%, sans condensation |
Facteur de salinité | 0,0 à 50,0 ppt |
Plage de saturation en pourcentage (RDO) | 0.0 to 600.0% saturation |
Percent Saturation Relative Accuracy (RDO) | ±2% saturation |
Précision (RDO) | ±2% saturation; ±0.02 mg/L or ppm |
Résolution (température) | 0,1°C, 0,1°F |
Thermo Scientific™ Orion™ Pro Star MP218 pH/ion, Conductivity and DO Bench Meter
Designed to provide accurate and reliable pH, ORP, ion, conductivity, TDS, salinity, resistivity, DO, barometric pressure and temperature analysis, the Thermo Scientific™ Orion™ Pro Star MP218 bench meter is well suited for laboratories that desire a modern meter with advance performance.
Certifications/Conformité | CE, TUV 3-1, FCC classe A |
---|---|
Clavier | Capacitive touchscreen user interface |
Précision (résistivité) | ±0.5% reading |
Measurement Modes | pH,ORP,mV,Ion Concentration (ISE),Conductivity,Dissolved Oxygen (mg/L),Temperature,Barometric Pressure |
Langues | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
Modèle | MP218 |
Option de rétro-éclairage | Oui |
Fonctions d’ionométrie avancées | Single known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction |
Précision de la température | ±0,3°C / ±0,5°F |
Points d’étalonnage (pH) | 1 to 5 points |
Poids (métrique) | 1.00 kg |
Gamme (OD) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
Sorties d’alarme | Calibration reminder alarm, high and low limit alarm per parameter |
Type de fonction d’enregistrement | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
Résolution (pH) | 0.1, 0.01 or 0.001 pH |
Percent Saturation Range Polarographic DO | Saturation de 0,0 à 600,0% |
Résolution (rH) | 0.1 mV |
Entrées | Channel 1: BNC for pH, ORP or ISE, 8-pin MiniDIN for ATC, pin-tip for reference; Channel 2: 8-pin MiniDIN for conductivity with ATC; Channel 3: 9-pin MiniDIN for dissolved oxygen with ATC |
Étalonnage | pH, ORP, Ion Concentration, Conductivity, TDS, Salinity, DO, Barometric Pressure, Temperature |
Température (métrique) de référence | 5, 10, 15, 20, 25 or 30°C |
Résolution (conductivité) | 0.001 μS/cm minimum, auto-ranging, up to 4 digits |
Type d’affichage | 7-in. High-resolution Color Graphic LCD |
Gamme (RDO) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
Gamme (mV relative) | -2000 to 2000 mV |
Mémoire | Non-volatile |
Précision (DO) | ±2% saturation; ±0.02 mg/L or ppm |
Poids (impériale) | 2.20 lbs. |
Précision (baromètre) | ±6.0 mmHg; ±0.008 bar |
Résolution (mV) | 0.1 mV |
Plage de températures (métrique) | -30.0°C to +130.0°C |
Facteur de salinité | 0.0 to 50.0 ppt; automatic with conductivity measurement or manual entry |
Plage de saturation en pourcentage (RDO) | 0.0 to 600.0% saturation |
Percent Saturation Relative Accuracy (RDO) | ±2% saturation |
Précision (TDS) | ±0.5% reading |
Précision (salinité) | ±0.5% reading |
Sélection de la température | Automatic with ATC temperature sensor, ambient or manual |
Compensation thermique | Linear (0.00 to 10.00 %/°C), nLFn (non-linear natural water), nLFu (non-linear ultra-pure water), EP/USP or off |
Type de sonde | Polarographic or optical DO electrode |
Résolution de la température | 0,1°C, 0,1°F |
Gamme (rH) | -2000 to 2000 mV |
Résolution (ionométrie) | 0.0001 minimum, 1 to 5 digits |
Résolution du coefficient de saturation (RDO) | 0,1, saturation de 1 % |
Correction de la pression barométrique | Yes, automatic with built-in barometer or manual |
Résolution (ion) | 0.0001 minimum, 1 to 5 digits |
Précision (pH) | ±0.002 pH |
Dimensions (L x l x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
Garantie | 2 year meter warranty |
Précision (rH) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
Résolution (TDS) | 0.001 ppm or mg/L minimum, auto-ranging, up to 4 digits |
Gamme (ions spécifiques) | 0.0001 to 19999 |
Précision (OD par mesure polarographique) | ±2% saturation; ±0.02 mg/L or ppm |
Adaptateur secteur | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
Point isopotentiel | 7.000 pH; 1.000 ion concentration |
Canaux | 3 |
Points d’étalonnage (conductivité) | 1 to 5 points |
Résolution (OD) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
Modes de mesure de la salinité | Natural Seawater (ppt), Practical Salinity Units (PSU), or % NaCl |
Gamme (salinité) | 0.010 to 80.00 ppt; 0.01 to 42.00 PSU; or 0.01 to 400.0% NaCl |
Sorties | USB flash drive, computer or printer (STARA-106) |
Méthodes | 10 per channel (30 total) |
Gamme de facteurs TDS | Linear (0.01 to 10.00), ISO/EN 27888, 442, NaCl |
Gamme (OD par mesure polarographique) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
Indice IP | IP54 |
Percent Saturation Relative Accuracy (Polarographic DO) | ±2% saturation |
Gamme (résistivité) | 1.0Ω to 100.0 MΩ |
Points de données | 10,000 with Date and Time Stamp |
Points d’étalonnage (ionométrie) | Up to 5 |
Précision (conductivité) | ±0.5% reading |
Gamme de pression | 400.0 to 850.0 mmHg; 0.533 to 1.133 bar |
Étalonnage de la sonde de température | 1 or 2 point temperature offset calibration |
Constante de cellule | 0.100 cm-1, 0.475 cm-1, 0.550 cm-1, 1.000 cm-1, 10.00 cm-1 or user-defined from 0.001 to 199.9 cm-1 |
Résolution (salinité) | 0.001 ppt minimum; 0.01 PSU minimum; or 0.01% NaCl minimum, auto-ranging |
Résolution (résistivité) | 0.1 Ωminimum, auto-ranging |
Gamme (TDS) | 0.010 ppm to 500.0 ppt (TDS factor of 1.00); or 0.010 mg/L to 500.0 g/L (TDS factor of 1.00) |
Résolution (OD par mesure polarographique) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
Points d’étalonnage | 1 to 5 (pH), 1 (ORP), 1 to 5 (ion), 1 to 5 (conductivity), 1 to 5 (TDS), 1 (salinity), 1 to 2 (DO), 1 (barometer), 1 to 2 (temperature) |
Modes d’étalonnage | Water-saturated air (100% and 0% saturation), air-saturated water (100% and 0% saturation) or custom concentration value (Winkler) |
Gamme (ion) | 0.0001 to 19999 |
Gamme (mV) | -2000 à 2000 mV |
Percent Saturation Resolution (Polarographic DO) | 0,1, saturation de 1 % |
Précision (mV) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
Résolution (RDO) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
Gamme (pH) | -2 à 20 |
Plage de températures (impériale) | -22.0°F to +266.0°F |
Gamme (conductivité) | 0.010 μS/cm to 3000 mS/cm |
Précision (RDO) | ±2% saturation; ±0.02 mg/L or ppm |
Précision (ions spécifiques) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
Thermo Scientific™ Orion™ Pro Star PI214 pH/ion Bench Meter
Designed to provide accurate and reliable pH, ORP, ion concentration and temperature analysis, the Thermo Scientific™ Orion™ Pro Star PI214 bench meter is well suited for laboratories that desire a modern meter with advance performance.
Certifications/Conformité | CE, TUV 3-1, FCC Class A |
---|---|
Sélection de la température | Automatic with ATC temperature sensor, ambient or manual |
Clavier | Capacitive touchscreen user interface |
Gamme (rH) | -2000 to 2000 mV |
Résolution (ionométrie) | 0.0001 minimum, 1 to 5 digits |
Précision (pH) | ±0.002 pH |
Dimensions (L x l x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
Garantie | 2 year meter warranty |
Measurement Modes | pH with mV and Temperature,ORP with mV and Temperature,Ion Concentration (ISE) with Temperature |
Adaptateur secteur | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
Langues | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
Point isopotentiel | 7.000 pH; 1.000 ion concentration |
Canaux | 1 |
Modèle | PI214 |
Option de rétro-éclairage | Oui |
Sorties | USB flash drive, computer or printer (STARA-106) |
Fonctions d’ionométrie avancées | Single known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction |
Méthodes | 10 |
Gamme (ionométrie) | 0.0001 to 19999 |
Points de données | 10,000 with Date and Time Stamp |
Points d’étalonnage (pH) | 1 to 5 points |
Poids (métrique) | 1.00 kg |
Points d’étalonnage (ionométrie) | Up to 5 |
Sorties d’alarme | Calibration reminder alarm, high and low limit alarm per parameter |
Étalonnage de la sonde de température | 1 or 2 point temperature offset calibration |
Type de fonction d’enregistrement | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
Résolution (pH) | 0.1, 0.01 or 0.001 pH |
Points d’étalonnage | 1 to 5 (pH), 1 (ORP), 1 to 5 (ion), 1 to 2 (temperature) |
Précision (température) | ±0.3°C, ±0.5°F |
Entrées | BNC for pH, ORP or ion selective electrode (ISE), 8-pin MiniDIN for ATC, pin-tip for reference |
Étalonnage | pH, ORP, Ion Concentration, Temperature |
Gamme (mV) | -2000 to 2000 mV |
Type d’affichage | 7-in. High-resolution Color Graphic LCD |
Gamme (mV relative) | -2000 to 2000 mV |
Mémoire | Non-volatile |
Plage (métrique) de températures | -30.0°C to +130.0°C |
Poids (impériale) | 2.20 lbs. |
Précision (mV) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
Résolution (mV) | 0.1 mV |
Gamme (pH) | -2 to 20 |
Résolution (température) | 0,1°C, 0,1°F |
Précision (ions spécifiques) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
Thermo Scientific™ Orion™ Pro Star PD216 pH/ion and DO Bench Meter
Designed to provide accurate and reliable pH, ORP, ion concentration, dissolved oxygen, barometric pressure and temperature analysis, the Thermo Scientific™ Orion™ Pro Star PD216 bench meter is well suited for laboratories that desire a modern meter with advance performance.
Certifications/Conformité | CE, TUV 3-1, FCC classe A |
---|---|
Clavier | Capacitive touchscreen user interface |
Measurement Modes | pH,ORP,mV,Ion Concentration (ISE),Dissolved Oxygen (mg/L),Dissolved Oxygen (% Saturation),Temperature,Barometric Pressure |
Langues | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
Modèle | PD216 |
Option de rétro-éclairage | Oui |
Fonctions d’ionométrie avancées | Single known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction |
Précision de la température | ±0,3°C / ±0,5°F |
Points d’étalonnage (pH) | 1 to 5 points |
Poids (métrique) | 1.00 kg |
Gamme (OD) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
Sorties d’alarme | Calibration reminder alarm, high and low limit alarm per parameter |
Type de fonction d’enregistrement | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
Résolution (pH) | 0.1, 0.01 or 0.001 pH |
Percent Saturation Range Polarographic DO | Saturation de 0,0 à 600,0% |
Résolution (rH) | 0.1 mV |
Entrées | Channel 1: BNC for pH, ORP or ISE, 8-pin MiniDIN for ATC, pin-tip for reference; Channel 2: 9-pin MiniDIN for dissolved oxygen with ATC |
Étalonnage | pH, ORP, Ion Concentration, DO, Barometric Pressure, Temperature |
Type d’affichage | 7-in. High-resolution Color Graphic LCD |
Gamme (RDO) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
Gamme (mV relative) | -2000 to 2000 mV |
Mémoire | Non-volatile |
Précision (DO) | ±2% saturation; ±0.02 mg/L or ppm |
Poids (impériale) | 2.20 lbs. |
Précision (baromètre) | ±6.0 mmHg; ±0.008 bar |
Résolution (mV) | 0.1 mV |
Plage de températures (métrique) | -30.0°C to +130.0°C |
Facteur de salinité | 0.0 to 50.0 ppt |
Plage de saturation en pourcentage (RDO) | 0.0 to 600.0% saturation |
Percent Saturation Relative Accuracy (RDO) | ±2% saturation |
Sélection de la température | Automatic with ATC temperature sensor, ambient or manual |
Type de sonde | Polarographic or optical DO electrode |
Résolution de la température | 0,1°C, 0,1°F |
Gamme (rH) | -2000 to 2000 mV |
Résolution (ionométrie) | 0.0001 minimum, 1 to 5 digits |
Résolution du coefficient de saturation (RDO) | 0,1, saturation de 1 % |
Correction de la pression barométrique | Yes, automatic with built-in barometer or manual |
Résolution (ion) | 0.0001 minimum, 1 to 5 digits |
Précision (pH) | ±0.002 pH |
Dimensions (L x l x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
Garantie | 2 year meter warranty |
Précision (rH) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
Gamme (ions spécifiques) | 0.0001 to 19999 |
Précision (OD par mesure polarographique) | ±2% saturation; ±0.02 mg/L or ppm |
Adaptateur secteur | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
Point isopotentiel | 7.000 pH; 1.000 ion concentration |
Canaux | 2 |
Résolution (OD) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
Sorties | USB flash drive, computer or printer (STARA-106) |
Méthodes | 10 per channel (20 total) |
Gamme (OD par mesure polarographique) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
Indice IP | IP54 |
Percent Saturation Relative Accuracy (Polarographic DO) | ±2% saturation |
Points de données | 10,000 with Date and Time Stamp |
Points d’étalonnage (ionométrie) | Up to 5 |
Gamme de pression | 400.0 to 850.0 mmHg; 0.533 to 1.133 bar |
Étalonnage de la sonde de température | 1 or 2 point temperature offset calibration |
Résolution (OD par mesure polarographique) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
Points d’étalonnage | 1 to 5 (pH), 1 (ORP), 1 to 5 (ion), 1 to 2 (DO), 1 (barometer), 1 to 2 (temperature) |
Modes d’étalonnage | Water-saturated air (100% and 0% saturation), air-saturated water (100% and 0% saturation) or custom concentration value (Winkler) |
Gamme (ion) | 0.0001 to 19999 |
Gamme (mV) | -2000 à 2000 mV |
Percent Saturation Resolution (Polarographic DO) | 0,1, saturation de 1 % |
Précision (mV) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
Résolution (RDO) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
Gamme (pH) | -2 à 20 |
Plage de températures (impériale) | -22.0°F to +266.0°F |
Précision (RDO) | ±2% saturation; ±0.02 mg/L or ppm |
Précision (ions spécifiques) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
Thermo Scientific™ Orion™ Pro Star PI217 Dual Channel pH/Ion Bench Meter
Designed to provide accurate and reliable pH, ORP, ion concentration and temperature analysis, the Thermo Scientific™ Orion™ Pro Star PI217 dual channel bench meter is well suited for laboratories that desire a modern meter with advance performance.
Certifications/Conformité | CE, TUV 3-1, FCC Class A |
---|---|
Sélection de la température | Automatic with ATC temperature sensor, ambient or manual |
Clavier | Capacitive touchscreen user interface |
Gamme (rH) | -2000 to 2000 mV |
Résolution (ionométrie) | 0.0001 minimum, 1 to 5 digits |
Précision (pH) | ±0.002 pH |
Dimensions (L x l x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
Garantie | 2 year meter warranty |
Measurement Modes | pH,ORP with mV and Temperature,Ion Concentration (ISE) with Temperature |
Adaptateur secteur | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
Langues | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
Point isopotentiel | 7.000 pH; 1.000 ion concentration |
Canaux | 2 |
Modèle | PI217 |
Option de rétro-éclairage | Oui |
Sorties | USB flash drive, computer or printer (STARA-106) |
Fonctions d’ionométrie avancées | Single known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction |
Méthodes | 10 per channel (20 total) |
Gamme (ionométrie) | 0.0001 to 19999 |
Points de données | 10,000 with Date and Time Stamp |
Points d’étalonnage (pH) | 1 to 5 points |
Poids (métrique) | 1.00 kg |
Points d’étalonnage (ionométrie) | Up to 5 |
Sorties d’alarme | Calibration reminder alarm, high and low limit alarm per parameter |
Étalonnage de la sonde de température | 1 or 2 point temperature offset calibration |
Type de fonction d’enregistrement | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
Résolution (pH) | 0.1, 0.01 or 0.001 pH |
Points d’étalonnage | 1 to 5 (pH), 1 (ORP), 1 to 5 (ion), 1 to 2 (temperature) |
Précision (température) | ±0.3°C, ±0.5°F |
Entrées | Channel 1: BNC for pH, ORP or ISE, 8-pin MiniDIN for ATC, pin-tip for reference; Channel 2: BNC for pH, ORP or ISE, 8-pin MiniDIN for ATC, pin-tip for reference |
Étalonnage | pH, ORP, Ion Concentration, Temperature |
Gamme (mV) | -2000 to 2000 mV |
Type d’affichage | 7-in. High-resolution Color Graphic LCD |
Gamme (mV relative) | -2000 to 2000 mV |
Mémoire | Non-volatile |
Plage (métrique) de températures | -30.0°C to +130.0°C |
Poids (impériale) | 2.20 lbs. |
Précision (mV) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
Résolution (mV) | 0.1 mV |
Gamme (pH) | -2 to 20 |
Résolution (température) | 0,1°C, 0,1°F |
Précision (ions spécifiques) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
Thermo Scientific™ Orion™ Pro Star EC212 Conductivity Bench Meter with Stand
Designed to provide accurate and reliable conductivity, TDS, salinity, resistivity and temperature analysis, the Thermo Scientific™ Orion™ Pro Star EC212 bench meter is well suited for laboratories that desire a modern meter with advance performance.
Certifications/Conformité | CE, TUV 3-1, FCC classe A |
---|---|
Précision (résistivité) | ±0.5% reading |
Clavier | Capacitive touchscreen user interface |
Sélection de la température | Automatic with ATC temperature sensor, ambient or manual |
Compensation thermique | Linear (0.00 to 10.00 %/°C), nLFn (non-linear natural water), nLFu (non-linear ultra-pure water), EP/USP or off |
Garantie | 2 year meter warranty |
Dimensions (L x l x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
Adaptateur secteur | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
Résolution (TDS) | 0.001 ppm or mg/L minimum, auto-ranging, up to 4 digits |
Measurement Modes | Conductivity with Temperature,TDS with Temperature,Salinity with Temperature,Resistivity with Temperature |
Canaux | 1 |
Langues | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
Points d’étalonnage (conductivité) | 1 to 5 points |
Modèle | EC212 |
Option de rétro-éclairage | Oui |
Modes de mesure de la salinité | Natural Seawater (ppt), Practical Salinity Units (PSU), or % NaCl |
Gamme (salinité) | 0.010 to 80.00 ppt; 0.01 to 42.00 PSU; or 0.01 to 400.0% NaCl |
Sorties | USB flash drive, computer or printer (STARA-106) |
Méthodes | 10 |
Indice IP | IP54 |
Gamme de facteurs TDS | Linear (0.01 to 10.00), ISO/EN 27888, 442, NaCl |
Gamme (résistivité) | 1.0 Ω to 100.0 MΩ |
Points de données | 10,000 with Date and Time Stamp |
Poids (métrique) | 1 kg |
Précision (conductivité) | ±0.5% reading |
Sorties d’alarme | Calibration reminder alarm, high and low limit alarm per parameter |
Étalonnage de la sonde de température | 1 or 2 point temperature offset calibration |
Constante de cellule | 0.100 cm-1, 0.475 cm-1, 0.550 cm-1, 1.000 cm-1, 10.00 cm-1 or user-defined from 0.001 to 199.9 cm-1 |
Type de fonction d’enregistrement | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
Résolution (résistivité) | 0.1 Ω minimum, auto-ranging |
Gamme (TDS) | 0.010 ppm to 500.0 ppt (TDS factor of 1.00); or 0.010 mg/L to 500.0 g/L (TDS factor of 1.00) |
Résolution (salinité) | 0.001 ppt minimum; 0.01 PSU minimum; or 0.01% NaCl minimum, auto-ranging |
Précision (température) | ±0.3°C, ±0.5 °F |
Points d’étalonnage | 1 to 5 (conductivity), 1 to 5 (TDS), 1 (salinity), 1 to 2 (temperature) |
Entrées | 8-pin MiniDIN for conductivity with ATC |
Étalonnage | Conductivity, TDS, Salinity, Temperature |
Température (métrique) de référence | 5, 10, 15, 20, 25 or 30°C |
Type d’affichage | 7-in. High-resolution Color Graphic LCD |
Résolution (conductivité) | 0.001 μS/cm minimum, auto-ranging, up to 4 digits |
Mémoire | Non-volatile |
Poids (impériale) | 2.20 lbs. |
Plage de températures (métrique) | –30°C à +130°C |
Précision (TDS) | ±0.5% reading |
Résolution (température) | 0,1°C, 0,1°F |
Plage de températures (impériale) | -22°F to +266°F |
Précision (salinité) | ±0.5% reading |
Gamme (conductivité) | 0.010 μS/cm to 3000 mS/cm |
Thermo Scientific™ Orion™ Pro Star PC215 pH/ion and Conductivity Bench Meter with Stand
Designed to provide accurate and reliable pH, ORP, ion concentration, conductivity, TDS, salinity, resistivity and temperature analysis, the Thermo Scientific™ Orion™ Pro Star PC215 bench meter is well suited for laboratories that desire a modern meter with advance performance.
Certifications/Conformité | CE, TUV 3-1, FCC classe A |
---|---|
Clavier | Capacitive touchscreen user interface |
Précision (résistivité) | ±0.5% reading |
Langues | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
Modèle | PC215 |
Option de rétro-éclairage | Oui |
Fonctions d’ionométrie avancées | Single known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction |
Précision de la température | ±0,3°C / ±0,5°F |
Points d’étalonnage (pH) | 1 to 5 points |
Poids (métrique) | 1.00 kg |
Sorties d’alarme | Calibration reminder alarm, high and low limit alarm per parameter |
Type de fonction d’enregistrement | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
Résolution (pH) | 0.1, 0.01 or 0.001 pH |
Résolution (rH) | 0.1 mV |
Entrées | Channel 1: BNC for pH, ORP or ISE, 8-pin MiniDIN for ATC, pin-tip for reference; Channel 2: 8-pin MiniDIN for conductivity with ATC |
Étalonnage | pH, ORP, Ion Concentration, Conductivity, TDS, Salinity, Temperature |
Température (métrique) de référence | 5, 10, 15, 20, 25 or 30°C |
Résolution (conductivité) | 0.001 μS/cm minimum, auto-ranging, up to 4 digits |
Type d’affichage | 7-in. High-resolution Color Graphic LCD |
Gamme (mV relative) | -2000 to 2000 mV |
Mémoire | Non-volatile |
Poids (impériale) | 2.20 lbs. |
Résolution (mV) | 0.1 mV |
Plage de températures (métrique) | -30.0°C to +130.0°C |
Précision (TDS) | ±0.5% reading |
Précision (salinité) | ±0.5% reading |
Sélection de la température | Automatic with ATC temperature sensor, ambient or manual |
Compensation thermique | Linear (0.00 to 10.00 %/°C), nLFn (non-linear natural water), nLFu (non-linear ultra-pure water), EP/USP or off |
Résolution de la température | 0,1°C, 0,1°F |
Gamme (rH) | -2000 to 2000 mV |
Résolution (ionométrie) | 0.0001 minimum, 1 to 5 digits |
Résolution (ion) | 0.0001 minimum, 1 to 5 digits |
Précision (pH) | ±0.002 pH |
Dimensions (L x l x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
Garantie | 2 year meter warranty |
Précision (rH) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
Résolution (TDS) | 0.001 ppm or mg/L minimum, auto-ranging, up to 4 digits |
Gamme (ions spécifiques) | 0.0001 to 19999 |
Adaptateur secteur | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
Point isopotentiel | 7.000 pH; 1.000 ion concentration |
Canaux | 2 |
Points d’étalonnage (conductivité) | 1 to 5 points |
Modes de mesure de la salinité | Natural Seawater (ppt), Practical Salinity Units (PSU), or % NaCl |
Gamme (salinité) | 0.010 to 80.00 ppt; 0.01 to 42.00 PSU; or 0.01 to 400.0% NaCl |
Sorties | USB flash drive, computer or printer (STARA-106) |
Méthodes | 10 per channel (20 total) |
Gamme de facteurs TDS | Linear (0.01 to 10.00), ISO/EN 27888, 442, NaCl |
Indice IP | IP54 |
Gamme (résistivité) | 1.0 Ω to 100.0 MΩ |
Points de données | 10,000 with Date and Time Stamp |
Points d’étalonnage (ionométrie) | Up to 5 |
Précision (conductivité) | ±0.5% reading |
Étalonnage de la sonde de température | 1 or 2 point temperature offset calibration |
Constante de cellule | 0.100 cm-1, 0.475 cm-1, 0.550 cm-1, 1.000 cm-1, 10.00 cm-1 or user-defined from 0.001 to 199.9 cm-1 |
Résolution (salinité) | 0.001 ppt minimum; 0.01 PSU minimum; or 0.01% NaCl minimum, auto-ranging |
Résolution (résistivité) | 0.1 Ω minimum, auto-ranging |
Gamme (TDS) | 0.010 ppm to 500.0 ppt (TDS factor of 1.00); or 0.010 mg/L to 500.0 g/L (TDS factor of 1.00) |
Points d’étalonnage | 1 to 5 (pH), 1 (ORP), 1 to 5 (ion), 1 to 5 (conductivity), 1 to 5 (TDS), 1 (salinity), 1 to 2 (temperature) |
Gamme (ion) | 0.0001 to 19999 |
Gamme (mV) | -2000 à 2000 mV |
Précision (mV) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
Gamme (pH) | -2 à 20 |
Plage de températures (impériale) | -22.0°F to +266.0°F |
Gamme (conductivité) | 0.010 μS/cm to 3000 mS/cm |
Précision (ions spécifiques) | ±0.2 mV or ±0.05% of the reading, whichever is greater |