missing translation for 'onlineSavingsMsg'
Learn More

Invitrogen™ Kit SYBR™ Green Fast Advanced Cells-to-CT™
GREENER_CHOICE

Le kit SYBR Green Fast Advanced Cells-to-Ct est un système complet de lysat cellulaire conçu pour l’analyse de l’expression génétique directement à partir de cellules cultivées sans purification d’ARN.

Marque:  Invitrogen™ A35380

 Afficher plus de versions de ce produit

Code produit. 16366532

  • 1624.00€ / 100 réactions

Veuillez vous pour pouvoir commander cet article. Besoin d'un compte web? Créer le vôtre dès maintenant!

Découvrez plus d'offres spéciales

Includes: Réactif de lyse cellulaire, DNase I, solution d’arrêt, mélange enzymatique RT 20X, tampon RT 2X, mélange Cells-to-Ct SYBR Fast Advanced Master Mix
Les retours ne sont pas autorisés pour ce produit. Afficher la politique du retour.

Description

Description

The SYBR Green Fast Advanced Cells-to-Ct Kit is a complete cell lysate system designed for gene expression analysis directly from cultured cells without RNA purification. SYBR Green Fast Advanced Cells-to-Ct cell lysis reagents are supplied with highest sensitivity Cells-to-Ct Fast Advanced reverse transcription enzyme mix, 2X RT buffer, and best-in-class PowerUp SYBR Green Master mix. The SYBR Green Fast Advanced Cells-to-Ct Kit gives you the sensitivity you need in the fastest workflow available: get gene expressions analysis results from an entire plate of cells in about 1.5 hours.

Complete—optimized workflow includes cell lysis reagents with gDNA removal, new Fast Advanced RT enzyme mix, buffer, and new PowerUp SYBR Green Fast Advanced Master Mix
Fast—7-minute sample prep, including DNase treatment, at room temperature
Easy—lyse samples in a tube or directly in culture plates
Robust—perform gene expression analysis on 10–100,000 cells per sample; results equivalent to those from purified RNA
Efficient—contains sufficient reagents to generate 1000 real-time PCR results from 100 starting samples

Unique method eliminates the need to isolate RNA from cultured cells
The Cells-to-Ct method features a unique lysis reagent that lyses cells and protects RNA. DNA removal occurs simultaneously in the 5-minute lysis step to save time and improve ease of use. Lysis is then stopped by the addition of a “Stop Solution” that irreversibly binds to the lysis reagents.

The SYBR Green Fast Advanced Cells-to-CT Kit contains Cells-to-Ct Fast Advanced reverse transcription (RT) reagents for cDNA synthesis and PowerUp SYBR Green Master Mix for real-time PCR analysis. Primer sets are provided by the user.

Simple 7-minute sample preparation
The SYBR Green Fast Advanced Cells-to-CT Kit is designed for 10–100,000 cultured cells/sample. Cells are washed in PBS and lysed in lysis solution for five minutes at room temperature; DNase treatment can be performed simultaneously. Lysis is terminated at room temperature by a 2-minute incubation with Stop Solution. The lysates are now ready for reverse transcription or storage at –20°C for a short term or -80C for a long term.

Maximize sensitivity of detection
Unlike some competitor kits that limit the amount of lysate in the RT reaction to 10%, the SYBR Green Fast Advanced Cells-to-CT Kit can accommodate 45% of the total RT reaction volume as cell lysate. Additionally, cDNA can comprise up to 30% of the real-time PCR reaction volume. The large lysate volume in the optimized RT reaction, along with the large cDNA volume in the subsequent real-time PCR using the PowerUP SYBR Green Master Mix, lead to maximum sensitivity. The master mix amplifies the target precisely and accurately, enabling the detection of small quantities of target, such as transcripts expressed at low levels.

Reduced sample loss and transfer error
Because samples can be processed directly in culture wells (96 or 384 wells), sample handling and the potential for sample loss or transfer error are minimized, facilitating rapid, high-throughput processing. Unlike old-fashioned, multi-step RNA isolation protocols, no heating, washing, or centrifugation steps are required. The kit greatly simplifies a laborious 30–60 minute process and reduces it to 7 minutes.

Proven performance, proven together
All components of the SYBR Green Fast Advanced Cells-to-CT Kit have been optimized for consistent and reliable performance. This removes the guesswork involved in assembling separate sample preparation, RT, and real-time PCR kits, giving you the sensitivity you need in the fastest sample-to-answer workflow available.

TRUSTED_SUSTAINABILITY
Spécification

Spécification

• Mélange enzymatique de RT Fast Advanced 20X 250 μl
• 5 ml de tampon RT Fast Advanced 2X
• 5 ml de solution de lyse
• 550 μl de solution d’arrêt
• 55 μl de DNase I
• 5 ml de mélange PowerUp SYBR Green Master Mix

Conserver entre -5 et -30°C.
Tube
RT-qPCR en 2 étape
55 μl de DNase I.
Compatible avec le haut débit
Kit Fast Advanced Cells-to-Ct
100 réactions
2X
100 réactions
Lyse cellulaire
SYBR
Haut
Rapidité
Moins de ressources utilisées et moins de déchets, moins dangereux
Cells-to-CT™
Glace carbonique