Promotion on Water Purification

Enter promotion code 15762 to access the promotional prices until 31st July 2021.

Lab Booster -
Water Purification

Your Equipment Promotion

Save up to 45% on Water Purification
Water Purification






    Catalogue No. Description Price Stock Quantity  
success
11307051 Details
GENPURE PRO UV-TOC 10251.00€
En stock
pour voir le stock disponible 
Add to Basket
  
Product Specifications
Height (Metric) 615 mm
Height (English) 24.2 in.
Description GenPure Pro ultrapure water system with UV-photo-oxidation and TOC monitor
Model Barnstead GenPure Pro UV – TOC
Feedwater Connector 3/4 in. NPT
Conductivity 0.055µS/cm
Type Water Purification System
Width (English) 13 in.
Temperature Range (Metric) 2°C to 35°C
Product Water Type Type 1
Bacterial Content <0.01 CFU/mL
TOC Monitor with UV Intensity Monitoring Yes
Resistivity 18.2 Mohm.cm
Electrical Requirements 90/240 V 50/60 Hz
Depth (English) 18.6 in.
Power Consumption 0.1 kW
Feed Water Monitoring Integrated
Flow Rate Up to 2 L/min.
Total Organic Carbon 1 to 5 ppb
Voltage 90/240 V
Operating Pressure 2 to 6 bar
Depth (Metric) 472 mm
Frequency 50/60 Hz
Particles >0.2µM/mL <1
Width (Metric) 330 mm
11317051 Details
GENPURE PRO UV/UF-TOC 10954.50€
En stock
pour voir le stock disponible 
Add to Basket
  
Product Specifications
Height (English) 24.2 in.
Model Barnstead GenPure Pro UV/UF – TOC
Feedwater Connector 3/4 in. NPT
Type Water Purification System
Resistivity 18.2 Mohm.cm
Feed Water Monitoring Integrated
Depth (English) 18.6 in.
Total Organic Carbon 1 to 5 ppb
Voltage 90/240 V
Frequency 50/60 Hz
Particles >0.2µM/mL <1
Height (Metric) 615 mm
Description GenPure Pro ultrapure water system with UV-photo-oxidation, ultrafiltration membrane, and TOC monitor
Conductivity 0.055µS/cm
Temperature Range (Metric) 2°C to 35°C
Width (English) 13 in.
Product Water Type Type 1
TOC Monitor with UV Intensity Monitoring Yes
Bacterial Content <0.01 CFU/mL
Power Consumption 0.1 kW
Electrical Requirements 90/240 V 50/60 Hz
Flow Rate Up to 2 L/min.
Endotoxin Concentration <0.001 EU/mL
Operating Pressure 2 to 6 bar
Depth (Metric) 472 mm
Width (Metric) 330 mm
11387041 Details
GENPURE PRO UF/UV 9989.70€
En stock
pour voir le stock disponible 
Add to Basket
  
Product Specifications
Height (English) 24.2 in.
Model Barnstead GenPure Pro UV/UF
Feedwater Connector 3/4 in. NPT
Type Water Purification System
Resistivity 18.2 Mohm.cm
Feed Water Monitoring Integrated
Depth (English) 18.6 in.
Total Organic Carbon 1 to 5 ppb
Voltage 90/240 V
Frequency 50/60 Hz
Particles >0.2µM/mL <1
Height (Metric) 615 mm
Description GenPure Pro ultrapure water system with UV-photo-oxidation and ultrafiltration membrane
Conductivity 0.055µS/cm
Temperature Range (Metric) 2°C to 35°C
Width (English) 13 in.
Product Water Type Type 1
TOC Monitor with UV Intensity Monitoring Yes
Bacterial Content <0.01 CFU/mL
Power Consumption 0.1 kW
Electrical Requirements 90/240 V 50/60 Hz
Flow Rate Up to 2 L/min.
Endotoxin Concentration <0.001 EU/mL
Operating Pressure 2 to 6 bar
Depth (Metric) 472 mm
Width (Metric) 330 mm
15980206 Details
Smart2Pure Pro UV/UF 16 LPH with 30 L Re-circulation Tank, Pretreatment and Wall Mount 13869.00€
En stock
pour voir le stock disponible 
Add to Basket
  
Product Specifications
Bacterial retention 0.99
Model Smart2Pure Pro 16 UV/UF with 30L Tank - Complete system
Feedwater Connector 3/4 in. NPT and 1/2 in. NPT
Type Water Purification System
Weight (Metric) 22 kg
Permeate performance 16 L/hr. at 10°C
Includes Complete system includes Barnstead Pretreatment system with cartridges, RO/pretreatment cartridge, an ultrapure polisher cartridge, sterile 0.1 μm filter, UV lamp, UF filter, 30 L tank, CO2 vent filter, sterile overflow and system wall bracket
Feed Water Monitoring No
Total Organic Carbon 1 to 5 ppb
Feedwater Pressure 1 to 6 bar
Voltage 100/240 V
Frequency 50/60 Hz
Particles >0.2µM/mL <1
Height (Metric) 545 mm
Feedwater Source Tap
Conductivity Type 1: 0.055μS/cm and Type II: 0.067 to 0.1μS/cm
RO Flow Rate 16 L/hr.
Product Water Type Type 1 and 2
TOC Monitor with UV Intensity Monitoring No
Bacterial Content <0.01 CFU/mL
Power Consumption 0.12 kW
Electrical Requirements 100/240 V 50/60 Hz
Flow Rate Up to 1 L/min.
Operating Pressure 1 to 6 bar
Depth (Metric) 300 mm
Width (Metric) 305 mm
15970206 Details
Smart2Pure Pro UV/UF 16 LPH with 60 L Re-circulation Tank, Pretreatment and Wall Mount 15276.00€
Expédition estimée: 18-12-2028
pour voir le stock disponible 
Add to Basket
  
Product Specifications
Bacterial retention 0.99
Model Smart2Pure Pro 16 UV/UF with 60L Tank - Complete system
Feedwater Connector 3/4 in. NPT and 1/2 in. NPT
Type Water Purification System
Weight (Metric) 22 kg
Permeate performance 16 L/hr. at 10°C
Includes Complete system includes Barnstead Pretreatment system with cartridges, RO/pretreatment cartridge, an ultrapure polisher cartridge, sterile 0.1 μm filter, UV lamp, UF filter, 60 L tank, CO2 vent filter, sterile overflow and system wall bracket
Feed Water Monitoring No
Total Organic Carbon 1 to 5 ppb
Feedwater Pressure 1 to 6 bar
Voltage 100/240 V
Frequency 50/60 Hz
Particles >0.2µM/mL <1
Height (Metric) 545 mm
Feedwater Source Tap
Conductivity Type 1: 0.055μS/cm and Type II: 0.067 to 0.1μS/cm
RO Flow Rate 16 L/hr.
Product Water Type Type 1 and 2
TOC Monitor with UV Intensity Monitoring No
Bacterial Content <0.01 CFU/mL
Power Consumption 0.12 kW
Electrical Requirements 100/240 V 50/60 Hz
Flow Rate Up to 1 L/min.
Operating Pressure 1 to 6 bar
Depth (Metric) 300 mm
Width (Metric) 305 mm
11397041 Details
GenPure Pro ultrapure water system withUV-photo-oxidation 9457.05€
En stock
pour voir le stock disponible 
Add to Basket
  
Product Specifications
Height (Metric) 615 mm
Height (English) 24.2 in.
Description GenPure Pro ultrapure water system with UV-photo-oxidation
Model Barnstead GenPure Pro UV
Feedwater Connector 3/4 in. NPT
Conductivity 0.055µS/cm
Type Water Purification System
Width (English) 13 in.
Temperature Range (Metric) 2°C to 35°C
Product Water Type Type 1
Bacterial Content <0.01 CFU/mL
TOC Monitor with UV Intensity Monitoring Yes
Resistivity 18.2 Mohm.cm
Electrical Requirements 90/240 V 50/60 Hz
Depth (English) 18.6 in.
Power Consumption 0.1 kW
Feed Water Monitoring Integrated
Flow Rate Up to 2 L/min.
Total Organic Carbon 1 to 5 ppb
Voltage 90/240 V
Operating Pressure 2 to 6 bar
Depth (Metric) 472 mm
Frequency 50/60 Hz
Particles >0.2µM/mL <1
Width (Metric) 330 mm



Learn More About The Fisher Scientific Channel


Register for an
Account

Join Our Live Webinars or
Watch a Replay

Sign up for News

Discover Our Online
Capabilities